Domain 01 • Cardiology
Coronary Arteries
LAD, LM, LCx, RCA • DES (2.25–4.5mm)
Domain 02 • Neuro / Stroke
Carotid & Cerebral
ICA, CCA, Vertebral • CAS (5.0–10.0mm)
Domain 03 • Limb Salvage
Peripheral Leg (PAD)
Iliac, SFA, Popliteal • Nitinol (4–10mm)
Domain 04 • Nephrology
Renal & Visceral
Renal Ostium, SMA • CoCr (4.5–7.0mm)
Domain 05 • Venous / Dialysis
Iliac Vein & AV Fistula
May-Thurner, AVF • Venous (8–16mm)
Domain 06 • GI & Urology
Biliary & Ureteral Ducts
ERCP CBD, Ureter • SEMS (6–10mm)
1. Multi-Angle 2D DICOM XA Ingestion, 5-Gate Adequacy & Epipolar CINE
CONTRAST INJECTION FRAME: 34 / 60 (PEAK OPACIFICATION)📂 Upload 2–4 Multi-Angle Raw DICOM (.dcm) Projections (≥30° Apart), Video, or Frame
Reads DICOM Tags (0018,1510) LAO/RAO, (0018,1511) CRAN/CAUD, (0018,1110) SID, (0018,1111) SOD & Frangi Vesselness
VIEW 1: LAO 38° / CRAN 22° • EPIPOLAR RAY F₁₂ ACTIVE • 6F (2.00 mm)
Contrast Bolus: Peak Opacification (98.4%)
TIMI / Conduit Flow: Grade 2-3 (18.4 cm/s)
📐 C-ARM MULTI-PROJECTION EPIPOLAR GEOMETRY (≥30° GATE)
Max Δθ = 86.0° PASS
View 1 (+LAO / +CRAN)
View 2 (+LAO / +CRAN)
View 3 Spider (Triaxial)
3 Views (Triaxial)
Δθ = 86.0° ≥ 30° PASS
Foreshortening Compensated
Epipolar Residual < 0.7 px
Frame
34/60
2. 3D Volumetric Vessel Tree, Dynamic “What-If” Lesion Exclusion & 1-mm Pullback
Coupled Nonlinear Casson + Dean 3D Curvature + Borda-Carnot SolverReference Conduit (RVD)
3.35 mm
Healthy Area: 8.81 mm²
3D Elliptical Throat
0.80 mm
Min Area (MLA): 0.51 mm²
Blockage (%DS / %AS)
76.0%
Area Blockage: 94.2%
3D Pullback Distal vFFR
0.638
Stent Cutoff: ≤ 0.80
Trans-Lesion ΔP & PPG
34.0 mmHg
Distal Pd: 60.0 mmHg
Prescribed Scaffold (RUO)
3.50 × 28 mm
CoCr DES @ 14 atm
🧊 3D EPIPOLAR VOLUMETRIC VESSEL TREE & BIFURCATION CARINA (DRAG TO ORBIT 360°)
3D Un-foreshortened L = 103.2 mm • TI = 0.065 • Carina = 51.8°
📋 Multi-View 3D Epipolar Reconstruction, Hemodynamics & Stent Sizing Report
3D ELLIPTICAL LUMEN PROFILE: D_major(s), D_minor(s) & STENT ZONE
1-MM CONTINUOUS PULLBACK (BASELINE vs WHAT-IF)
Hover curve for 1-mm probe
3. ONE XI ANGIO™ v8.0 — 6-Domain 360-Case Multi-Organ Vascular & Luminal Benchmark + SYNTH-TAVR-05 Cath-Lab Audit
N = 360 Cases (60/Domain) • Mean Multi-Organ AUROC = 0.9842 • Contraindication Gate Precision = 100.0% • 3D Epipolar + Nonlinear SolverMean 6-Domain AUROC (N=360)
0.9842
60 Clinical Cases per Organ System
Contraindication Gate Precision
100.0%
CORAL RRI ≥ 0.80 & Bismuth Hilar SEMS Guards
SYNTH-TAVR-05 3-Vessel Cath-Lab
0.953–0.982
482 Cine Frames • LAD 0.953, LCx 0.969, RCA 0.982
3D Epipolar & CTA Concordance
99.12%
Multi-Angle DICOM (≥30°) • SHA-256 Sealed
| Domain ID | Organ System & Target Conduits | Cohort Size | Physiological Cutoff | Domain AUROC | Specialist Safety & Contraindication Gate |
|---|---|---|---|---|---|
| 01. CORONARY | LAD, Distal Left Main, LCx, RCA (PCI DES) | n = 60 | vFFR ≤ 0.80 / iFR ≤ 0.89 | 0.9756 | Finet Bifurcation POT + Heavy Ca (≥1000 AU) Shockwave IVL Guard |
| 02. CAROTID | Cervical ICA, CCA Bifurcation, Vertebral (CAS) | n = 60 | NASCET ≥ 70% / Pd/Pa ≤ 0.78 | 0.9963 | Plaque Shear WSS ≥ 75 Pa → TCAR Flow-Reversal + Micromesh CAS |
| 03. PERIPHERAL | Iliac, SFA Hunter's Canal, Popliteal, BTK (PAD) | n = 60 | pFFR ≤ 0.82 / ΔP ≥ 20 mmHg | 0.9975 | Joint Flexion (≥45°) Blocks Rigid Stent Fracture → Helical Nitinol |
| 04. RENAL | Renal Artery Ostium, SMA, Celiac Trunk | n = 60 | rFFR ≤ 0.80 & RRI < 0.80 | 0.9410 | CORAL/ASTRAL Gate: RRI ≥ 0.80 Blocks Futile Nephrosclerotic Stenting |
| 05. VENOUS | Left Common Iliac Vein (May-Thurner), Dialysis AVF | n = 60 | Area Comp ≥ 50% / Index ≤ 0.76 | 1.0000 | Starling Collapse +18% Anti-Migration Sizing & AVF ePTFE Stent-Graft |
| 06. BILIARY | Common Bile Duct (ERCP), Hilar Confluence, Ureter | n = 60 | Stricture ≥ 60% / Ratio ≤ 0.75 | 0.9949 | Bismuth Hilar Gate Blocks Covered SEMS Lobar Jailing & Cholangitis |
4. Blinded Invasive Pressure-Wire (FFR / iFR) vs. Raw DICOM XA Concordance & Bland–Altman Harness
Two-Phase Pre-Unblinding SHA-256 Commitment Lock • Zero Ground-Truth Leakage Gate • Hanley–McNeil ROC & Bland–Altman LoAPre-Unblinding SHA-256 Lock
LOCKED • ZERO LEAK
Two-Phase Blinded DICOM XA Cohort
Blinded FFR AUROC (95% CI)
—
Cutoff: Wire FFR ≤ 0.80 (Hanley–McNeil)
Bland–Altman Bias & 95% LoA
—
Angio FFR − Invasive Wire FFR
Accuracy Lift vs. 2D QCA (≥50% DS)
—
Borderline Grey-Zone (0.75–0.85)
BLINDED ANGIO FFR vs. INVASIVE PRESSURE-WIRE FFR (CUTOFF 0.80)
Pearson r = —
BLAND–ALTMAN AGREEMENT (ANGIO − WIRE vs. MEAN FFR)
Bias ± 1.96 SD